Trace flag 3656 is not sufficient for symbol resolution on SQL Server 2019

You may have noticed that TF 3656 appears to no longer work in SQL Server 2019 RC1. Symbols are not resolved in Extended Events event data even with that trace flag enabled. Trace flag 2592 must also be enabled to resolve symbols. This was recently added by Microsoft to the documentation. This concludes the shortest blog post I will ever write.